{"id":55432,"date":"2024-07-19T15:49:45","date_gmt":"2024-07-19T13:49:45","guid":{"rendered":"https:\/\/aquariatech.com\/?post_type=product&#038;p=55432"},"modified":"2026-07-16T08:32:58","modified_gmt":"2026-07-16T06:32:58","slug":"hanna-instruments-valigetta-marine-master-checker-multiparametro-bluetooth","status":"publish","type":"product","link":"https:\/\/aquariatech.com\/en\/product\/hanna-instruments-valigetta-marine-master-checker-multiparametro-bluetooth","title":{"rendered":"Hanna Instruments &#8211; Marine Master BT &#8211; fornito in valigetta con accessori e reagenti per ogni parametro"},"content":{"rendered":"<h3><span style=\"color: #ff6600;\">The Manufacturer Informs:<\/span><\/h3>\n<p>HI97115 \u00e8 un fotometro multiparametro progettato per le analisi in\u00a0<strong>acque marine<\/strong>. Parametri misurati:\u00a0<strong>pH<\/strong>,\u00a0<strong>alcalinit\u00e0<\/strong>,\u00a0<strong>ammoniaca<\/strong>,\u00a0<strong>football<\/strong>,\u00a0<strong>magnesium<\/strong>,\u00a0<strong>nitrati<\/strong>,\u00a0<strong>nitriti<\/strong>,\u00a0<strong>fosfati<\/strong><\/p>\n<p style=\"font-weight: 400;\">Il sistema ottico avanzato con sorgente luminosa a LED permette di avere un\u2019elevata precisione rispetto ai classici Checker HC. Inoltre il sistema di bloccaggio delle cuvette garantisce il loro collocamento sempre nella stessa posizione, in modo da ottenere sempre letture accurate e ripetibili.<\/p>\n<p style=\"font-weight: 400;\">Attivando la funzione &#8220;Tutorial&#8221;, il display ti mostrer\u00e0 istruzioni dettagliate per ogni fase della procedura di analisi per ogni parametro. Questa funzione \u00e8 molto importante per prevenire dubbi e possibilit\u00e0 di errore.<\/p>\n<p style=\"font-weight: 400;\">Il fotometro registra in maniera automatica le ultime 200 misurazioni, inoltre \u00e8 possibile memorizzare fino a 10 diverse vasche. Tutti i risultati possono essere visualizzati istantaneamente premendo dal men\u00f9 il tasto \u201cRichiama\u201d.<\/p>\n<ul style=\"font-weight: 400;\">\n<li>Lo strumento \u00e8 dotato di un sistema ottico professionale, che utilizza un rilevatore di riferimento e una lente di focalizzazione per prevenire errori dovuti a possibili fluttuazioni nell&#8217;intensit\u00e0 della sorgente luminosa e alle imperfezioni della cuvetta in vetro.<\/li>\n<li>I LED, utilizzati come fonte di luce, hanno un&#8217;efficienza luminosa molto pi\u00f9 elevata, fornendo cos\u00ec pi\u00f9 luce e nello stesso tempo consumando meno energia. Inoltre producono poco calore, che altrimenti potrebbe influire sulla stabilit\u00e0 elettronica.<\/li>\n<li>Tutorial sempre disponibile, con istruzioni passo-passo che guidano l&#8217;utilizzatore durante le procedure di misura e calibrazione<\/li>\n<li>HI97105 dispone di una funzione di registrazione automatica dei dati per aiutare gli utenti a tenere traccia di tutte le loro analisi. Ogni volta che viene effettuata una misurazione, i dati vengono salvati automaticamente. Lo strumento pu\u00f2 contenere fino a 200 misurazioni.<\/li>\n<li>\u00c8 possibile memorizzare fino a 10 vasche, per poi salvare al loro interno le rispettive analisi<\/li>\n<li>Progettato per resistere ad urti e cadute; il nuovo corpo IP67 garantisce le massime prestazioni in qualsiasi ambiente. Marine Master \u00e8 protetto da polvere, sporco e acqua: nessun problema, nel caso HI97115 cadesse all&#8217;interno di una vasca, le parti elettroniche sono protette ed inoltre&#8230; lo strumento galleggia!<\/li>\n<li>Possibilit\u00e0 di connessione tramite bluetooth all&#8217;app Hanna Lab, salvando e condividendo i dati e controllando le impostazioni del dispositivo direttamente su smartphone<\/li>\n<\/ul>\n<p style=\"font-weight: 400;\">HI97115C viene fornito completo di:<\/p>\n<ul>\n<li style=\"font-weight: 400;\">HI772-26 Reagenti per Alcalinit\u00e0<br \/>\n\u2022HI758-26 Reagenti per Calcio<br \/>\n\u2022HI774-25 Reagenti per Fosfati ULR<br \/>\n\u2022HI764-25 Reagenti per Nitriti ULR<br \/>\n\u2022HI782-25 Reagenti per Nitrati HR<br \/>\n\u2022HI780-25 Reagenti per pH<br \/>\n\u2022HI783-25 Reagenti per Mg<br \/>\n\u2022Cuvette in vetro (2 pz.)<br \/>\n\u2022Tappi per cuvette (2 pz.)<br \/>\n\u2022Siringa graduata da 1 mL con puntali (2pz)<br \/>\n\u2022Micropipettacon puntale<br \/>\n\u2022Pipetta in plastica (2 pz.)<br \/>\n\u2022Batterie (3 pz.)<br \/>\n\u2022Forbici<br \/>\n\u2022Panno per pulizia cuvette<br \/>\n\u2022Certificato di qualit\u00e0<br \/>\n\u2022Manuale di istruzione<\/li>\n<\/ul>\n<p style=\"font-weight: 400;\">Per la misura dei Nitrati LR \u00e8 necessario acquistare separatamente i reagenti HI781-25.<\/p>\n<h1>Specifications:<\/h1>\n<p><strong>\u00a0<\/strong><\/p>\n<table width=\"699\">\n<tbody>\n<tr>\n<td rowspan=\"5\" width=\"125\">pH (Acqua marina)<\/td>\n<td width=\"135\">Scale<\/td>\n<td width=\"439\">da 6.3 a 8.6 pH<\/td>\n<\/tr>\n<tr>\n<td width=\"135\">Resolution<\/td>\n<td width=\"439\">0.1 pH<\/td>\n<\/tr>\n<tr>\n<td width=\"135\">Accuratezza<\/td>\n<td width=\"439\">\u00b10.2 pH della lettura a 25\u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"135\">Method<\/td>\n<td width=\"439\">Adattamento del metodo Fenolo Rosso<\/td>\n<\/tr>\n<tr>\n<td width=\"135\">Lunghezza d\u2019onda<\/td>\n<td width=\"439\">525 nm<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"5\" width=\"125\">Alcalinit\u00e0 (Acqua marina)<\/td>\n<td width=\"135\">Scale<\/td>\n<td width=\"439\">Da 0.0 a 20.0 dKH<\/td>\n<\/tr>\n<tr>\n<td width=\"135\">Resolution<\/td>\n<td width=\"439\">0.1 dKH<\/td>\n<\/tr>\n<tr>\n<td width=\"135\">Accuratezza<\/td>\n<td width=\"439\">\u00b10.3 dKH \u00b1 5% della lettura a 25\u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"135\">Method<\/td>\n<td width=\"439\">Metodo colorimetrico<br \/>\nLa reazione provoca lo sviluppo di una gamma distintiva di colori dal giallo al blu verdastro.<\/td>\n<\/tr>\n<tr>\n<td width=\"135\">Lunghezza d\u2019onda<\/td>\n<td width=\"439\">610 nm<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"5\" width=\"125\">Ammoniaca (Acqua Marina)<\/td>\n<td width=\"135\">Scale<\/td>\n<td width=\"439\">Da 0.00 a 2.50 ppm (come NH\u2083)<\/td>\n<\/tr>\n<tr>\n<td width=\"135\">Resolution<\/td>\n<td width=\"439\">0.01 ppm<\/td>\n<\/tr>\n<tr>\n<td width=\"135\">Accuratezza<\/td>\n<td width=\"439\">\u00b10.05 ppm \u00b15% della lettura a 25\u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"135\">Method<\/td>\n<td width=\"439\">Adaptation of the salicylate method. The reaction between ammonia and ammonium and the reagent causes a blue-green colouration in the sample.<\/td>\n<\/tr>\n<tr>\n<td width=\"135\">Lunghezza d\u2019onda<\/td>\n<td width=\"439\">610 nm<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"5\" width=\"125\">Calcio<br \/>\n(Acqua marina)<\/td>\n<td width=\"135\">Scale<\/td>\n<td width=\"439\">Da 200 a 600 ppm<\/td>\n<\/tr>\n<tr>\n<td width=\"135\">Resolution<\/td>\n<td width=\"439\">1 ppm<\/td>\n<\/tr>\n<tr>\n<td width=\"135\">Accuratezza<\/td>\n<td width=\"439\">\u00b16% della lettura a 25\u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"135\">Method<\/td>\n<td width=\"439\">Adattamento del metodo Zincon<\/td>\n<\/tr>\n<tr>\n<td width=\"135\">Lunghezza d\u2019onda<\/td>\n<td width=\"439\">610 nm<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"5\" width=\"125\">Magnesium<\/td>\n<td width=\"135\">Scale<\/td>\n<td width=\"439\">Da 1000 a 1800 ppm (come Mg2+)<\/td>\n<\/tr>\n<tr>\n<td width=\"135\">Resolution<\/td>\n<td width=\"439\">5 ppm<\/td>\n<\/tr>\n<tr>\n<td width=\"135\">Accuratezza<\/td>\n<td width=\"439\">\u00b15% della lettura a 25\u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"135\">Method<\/td>\n<td width=\"439\">Adattamento del metodo colorimetrico EDTA mediante indicatore calmagite. La reazione tra il magnesio e i reagenti provoca una colorazione da blu a viola nel campione<\/td>\n<\/tr>\n<tr>\n<td width=\"135\">Lunghezza d\u2019onda<\/td>\n<td width=\"439\">610 nm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p style=\"font-weight: 400;\"><strong>\u00a0<\/strong><\/p>\n<table width=\"699\">\n<tbody>\n<tr>\n<td rowspan=\"5\" width=\"131\">Nitrati Scala Bassa<br \/>\n(Acqua marina)<\/td>\n<td width=\"141\">Scale<\/td>\n<td width=\"427\">Da 0.00 a 5.00 ppm (come NO\u2083\u2013)<\/td>\n<\/tr>\n<tr>\n<td width=\"141\">Resolution<\/td>\n<td width=\"427\">0.01 ppm<\/td>\n<\/tr>\n<tr>\n<td width=\"141\">Accuratezza<\/td>\n<td width=\"427\">\u00b10.25 ppm \u00b12% della lettura a 25\u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"141\">Method<\/td>\n<td width=\"427\">Metodo riduzione Zinco. La reazione tra il nitrato e il reagente provoca una tinta rosa\/viola nel campione.<\/td>\n<\/tr>\n<tr>\n<td width=\"141\">Lunghezza d\u2019onda<\/td>\n<td width=\"427\">525 nm<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"5\" width=\"131\">Nitrati Scala Alta<br \/>\n(Acqua marina)<\/td>\n<td width=\"141\">Scale<\/td>\n<td width=\"427\">Da 0.0 a 75.0 ppm (come\u00a0NO\u2083\u2013)<\/td>\n<\/tr>\n<tr>\n<td width=\"141\">Resolution<\/td>\n<td width=\"427\">0.1 ppm<\/td>\n<\/tr>\n<tr>\n<td width=\"141\">Accuratezza<\/td>\n<td width=\"427\">\u00b12.0 ppm \u00b15% della lettura a 25\u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"141\">Method<\/td>\n<td width=\"427\">Metodo riduzione Zinco. La reazione tra il nitrato e il reagente provoca una tinta rosa\/viola nel campione.<\/td>\n<\/tr>\n<tr>\n<td width=\"141\">Lunghezza d\u2019onda<\/td>\n<td width=\"427\">525 nm<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"5\" width=\"131\">Nitriti (Acqua marina)<\/td>\n<td width=\"141\">Scale<\/td>\n<td width=\"427\">Da 0 a 200 ppb<\/td>\n<\/tr>\n<tr>\n<td width=\"141\">Resolution<\/td>\n<td width=\"427\">1 ppb<\/td>\n<\/tr>\n<tr>\n<td width=\"141\"><strong>\u00a0<\/strong><\/p>\n<p>Accuratezza<\/td>\n<td width=\"427\">\u00b110 ppb \u00b14% of reading at 25\u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"141\">Method<\/td>\n<td width=\"427\">Adattamento del metodo EPA Diazotizzazione 354.1<br \/>\nLa reazione tra il nitrito e il reagente provoca una colorazione rosa nel campione.<\/td>\n<\/tr>\n<tr>\n<td width=\"141\">Lunghezza d\u2019onda<\/td>\n<td width=\"427\">525 nm<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"5\" width=\"131\">Fosfati Scala Ultra Bassa<br \/>\n(Acqua marina)<\/td>\n<td width=\"141\">Scale<\/td>\n<td width=\"427\">Da 0.00 a 0.90 ppm<\/td>\n<\/tr>\n<tr>\n<td width=\"141\">Resolution<\/td>\n<td width=\"427\">0.01 ppm<\/td>\n<\/tr>\n<tr>\n<td width=\"141\">Accuratezza<\/td>\n<td width=\"427\">\u00b10.02 ppm \u00b15% della lettura a 25\u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"141\">Method<\/td>\n<td width=\"427\">Adattamento del Metodo Acido Ascorbico, dagli Standard Methods for the Examination of Water and Wastewater, 20th edition.\u00a0La reazione tra fosfati e reagente causa una colorazione blu del campione.<\/td>\n<\/tr>\n<tr>\n<td width=\"141\">Lunghezza d\u2019onda<\/td>\n<td width=\"427\">610 nm<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"8\" width=\"131\">Specifiche aggiuntive<\/td>\n<td width=\"141\">Auto registrazione<\/td>\n<td width=\"427\">Fino a 200 letture<\/td>\n<\/tr>\n<tr>\n<td width=\"141\">Display<\/td>\n<td width=\"427\">128 x 64 pixel B\/W con retroilluminazione<\/td>\n<\/tr>\n<tr>\n<td width=\"141\">Automatic switch-off<\/td>\n<td width=\"427\">Dopo 15 minuti di inattivit\u00e0 (30 minuti dopo la lettura)<\/td>\n<\/tr>\n<tr>\n<td width=\"141\">Tipo e durata batteria<\/td>\n<td width=\"427\">Alcaline 1.5 V AA (3 pz) \/ 800 misure (senza retroilluminazione)<\/td>\n<\/tr>\n<tr>\n<td width=\"141\">Conditions of Use<\/td>\n<td width=\"427\">Da 0 a 50\u00b0C; 0 a 100% RH<\/td>\n<\/tr>\n<tr>\n<td width=\"141\">Dimensione<\/td>\n<td width=\"427\">142.5x 102.5 x 50.5 mm<\/td>\n<\/tr>\n<tr>\n<td width=\"141\">Weight<\/td>\n<td width=\"427\">380 g con batterie<\/td>\n<\/tr>\n<tr>\n<td width=\"141\">Protezione<\/td>\n<td width=\"427\">IP67, galleggiante<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"excerpt":{"rendered":"<p>Il Produttore Informa: HI97115 \u00e8 un fotometro multiparametro progettato per le analisi in\u00a0acque marine. Parametri misurati:\u00a0pH,\u00a0alcalinit\u00e0,\u00a0ammoniaca,\u00a0calcio,\u00a0magnesio,\u00a0nitrati,\u00a0nitriti,\u00a0fosfati Il sistema ottico avanzato con sorgente luminosa a LED permette di avere un\u2019elevata precisione rispetto ai classici Checker HC. Inoltre il sistema di bloccaggio delle cuvette garantisce il loro collocamento sempre nella stessa posizione, in modo da ottenere sempre [&hellip;]<\/p>","protected":false},"featured_media":55431,"template":"","meta":[],"product_brand":[],"product_cat":[668],"product_tag":[1027],"class_list":{"0":"post-55432","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-controllo-e-misurazione","7":"product_tag-uso-negozio","8":"pa_brand_nc-hanna-instruments","10":"first","11":"instock","12":"taxable","13":"shipping-taxable","14":"purchasable","15":"product-type-simple"},"group_of_quantity":0,"min_quantity":0,"max_quantity":"","exclude_order_quantity_value_rules":"no","exclude_category_quantity_rules":"no","combine_variations":"no","_links":{"self":[{"href":"https:\/\/aquariatech.com\/en\/wp-json\/wp\/v2\/product\/55432","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/aquariatech.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/aquariatech.com\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/aquariatech.com\/en\/wp-json\/wp\/v2\/media\/55431"}],"wp:attachment":[{"href":"https:\/\/aquariatech.com\/en\/wp-json\/wp\/v2\/media?parent=55432"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/aquariatech.com\/en\/wp-json\/wp\/v2\/product_brand?post=55432"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/aquariatech.com\/en\/wp-json\/wp\/v2\/product_cat?post=55432"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/aquariatech.com\/en\/wp-json\/wp\/v2\/product_tag?post=55432"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}